ISSN 2394-5125
 

Research Article 


STUDY ON THE DIFFERENCE BETWEEN PRESSURE GAUGE AND PRESSURE TRANSDUCER AT ERBIL COMBINED CYCLE POWER STATION

Shivan Kareem ABDULLAH.

Abstract
The difference between pressure gauge indicator and pressure transducer has been studied and tested at Erbil combined cycle power station (ECCPS). The study performed on the gas fuel pipeline, both pressure gauge indicator and transducer are connected to the pipeline. The pressure gauge indicator placed in the field while the transducer sends the signal to the PC, it can be easily monitored on the PC. The results conclude that, the reading of pressure gauge indicator higher than the transducer with (0.9) bar maximum deviation. Gas turbine in (ECCPS) is running at the normal range of the gas fuel pressure (23-30) bar. Also, there is set point of gas fuel pressure which at (22.5) bar, send the alarm to (PC), also at (21.9) bar, the gas turbine will be auto shutdown.

Key words: Pressure gauge, pressure transducer, temperature indicate, temperature transducer


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Shivan Kareem ABDULLAH
on Google
on Google Scholar


How to Cite this Article
Pubmed Style

Shivan Kareem ABDULLAH. STUDY ON THE DIFFERENCE BETWEEN PRESSURE GAUGE AND PRESSURE TRANSDUCER AT ERBIL COMBINED CYCLE POWER STATION. JCR. 2021; 8(2): 979-986. doi:10.31838/jcr.08.02.102


Web Style

Shivan Kareem ABDULLAH. STUDY ON THE DIFFERENCE BETWEEN PRESSURE GAUGE AND PRESSURE TRANSDUCER AT ERBIL COMBINED CYCLE POWER STATION. http://www.jcreview.com/?mno=79271 [Access: May 07, 2021]. doi:10.31838/jcr.08.02.102


AMA (American Medical Association) Style

Shivan Kareem ABDULLAH. STUDY ON THE DIFFERENCE BETWEEN PRESSURE GAUGE AND PRESSURE TRANSDUCER AT ERBIL COMBINED CYCLE POWER STATION. JCR. 2021; 8(2): 979-986. doi:10.31838/jcr.08.02.102



Vancouver/ICMJE Style

Shivan Kareem ABDULLAH. STUDY ON THE DIFFERENCE BETWEEN PRESSURE GAUGE AND PRESSURE TRANSDUCER AT ERBIL COMBINED CYCLE POWER STATION. JCR. (2021), [cited May 07, 2021]; 8(2): 979-986. doi:10.31838/jcr.08.02.102



Harvard Style

Shivan Kareem ABDULLAH (2021) STUDY ON THE DIFFERENCE BETWEEN PRESSURE GAUGE AND PRESSURE TRANSDUCER AT ERBIL COMBINED CYCLE POWER STATION. JCR, 8 (2), 979-986. doi:10.31838/jcr.08.02.102



Turabian Style

Shivan Kareem ABDULLAH. 2021. STUDY ON THE DIFFERENCE BETWEEN PRESSURE GAUGE AND PRESSURE TRANSDUCER AT ERBIL COMBINED CYCLE POWER STATION. Journal of Critical Reviews, 8 (2), 979-986. doi:10.31838/jcr.08.02.102



Chicago Style

Shivan Kareem ABDULLAH. "STUDY ON THE DIFFERENCE BETWEEN PRESSURE GAUGE AND PRESSURE TRANSDUCER AT ERBIL COMBINED CYCLE POWER STATION." Journal of Critical Reviews 8 (2021), 979-986. doi:10.31838/jcr.08.02.102



MLA (The Modern Language Association) Style

Shivan Kareem ABDULLAH. "STUDY ON THE DIFFERENCE BETWEEN PRESSURE GAUGE AND PRESSURE TRANSDUCER AT ERBIL COMBINED CYCLE POWER STATION." Journal of Critical Reviews 8.2 (2021), 979-986. Print. doi:10.31838/jcr.08.02.102



APA (American Psychological Association) Style

Shivan Kareem ABDULLAH (2021) STUDY ON THE DIFFERENCE BETWEEN PRESSURE GAUGE AND PRESSURE TRANSDUCER AT ERBIL COMBINED CYCLE POWER STATION. Journal of Critical Reviews, 8 (2), 979-986. doi:10.31838/jcr.08.02.102